Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-D, SL-350TRS-IPI • 2120-900 Rev. D • 6/0722
Figure 5.12
Two 90º Elbows
3. Rear Vent - Horizontal Termination
Figure 5.10
No Elbow
H1 = 24 in. (610 mm) Maximum 90-DEGREE ELBOWS
H1 Maximum V1 Minimum H2H1 + H2 Maximum
1-1/2 ft. 457 mm Back to Back
Elbows 1 ft. 305 mm 2-1/2 ft. 762 mm
3-1/2 ft. 1.1 m 1 ft. 305 mm 3 ft. 914 mm 6-1/2 ft. 2.0 m
5-1/2 ft. 1.7 m 2 ft. 610 mm 5 ft. 1.5 m 10-1/2 ft. 3.2 m
7-1/2 ft. 2.3 m 3 ft. 914 mm 6-1/2 ft. 2.1 m 14 ft. 4.3 m
H1 Maximum = 7-1/2 ft. (2.3 m)
H1 + H2 Maximum = 14 ft. (4.3 m)
V1 + H1 + H2= 40 ft. (12.2 m)
Figure 5.11
Use two 90º elbows for corner installations.
The use of two 90º elbows in a corner installation
will affect space requirements.
Two 90º Elbows
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
H1
H1
H2V1