7Electrical Information

A. Recommendation for Wire

Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code,

CSA C22.1.

B. Connecting to the Appliance

C. Intellifire Ignition System Wiring

This appliance requires two “D” size batteries (3V) supply to the appliance valve for operation. A wiring diagram is shown in Figure 7.1.

This appliance is equipped with an Intellifi re control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack which is located inth e ON/OFF switch terminal box.

The battery pack requires two D cell batteries (not included).

WARNING

Shock Risk

Explosion Risk

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch

Incorrect wiring will damage millivolt values.

Incorrect wiring will override IPI safety lockout and may cause explosion.

This appliance may be used with a wall switch.

Use low resistance thermostat wire for wiring from ignition system to the wall switch.

Keep wire lengths short as possible by removing any excess wire length, not to exceed 18 ft.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

CAUTION

Battery polarity must be correct or module damage will occur.

CAUTION

Shock Risk

Replace damaged wire with type 105° C rated wire.

Wire must have high temperature insulation.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

 

IGNITION MODULE

 

I

 

 

 

 

3 VAC

 

 

INTERMITTENT

 

 

 

 

 

S

PILOT

 

 

 

 

 

IGNITOR

 

 

 

 

 

 

 

BATTERY

 

 

 

 

 

 

PACK

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

WALL

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

FLAME SPARKER/

 

 

 

WHT

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

IGNITION

 

BATTERY

 

 

ORG

 

MODULE

 

 

 

 

 

(3V)

 

PACK

BLACK

 

GROUND TO

 

 

 

 

 

FIREPLACE

 

 

 

 

 

CHASSIS

 

 

 

 

RED

 

 

 

VALVE

LOW VOLTAGE

 

BRN

BRN

 

 

 

SEE NOTE 1

 

ORG

 

 

 

 

GRN

 

 

 

PIGGYBACK

 

 

 

 

 

 

ON/OFF SWITCH

 

 

 

 

 

 

 

VALVE

 

Figure 7.1 Intellefire Pilot Ignition (IPI) Wiring Diagram

 

 

 

 

 

Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05

13

Page 13
Image 13
Heat & Glo LifeStyle DAKOTA 42H Electrical Information, Recommendation for Wire, CSA C22.1, Shock Risk Explosion Risk