3Framing and Clearances

Note:

Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

WARNING

Fire Risk

Provide adequate clearance:

Around air openings.

To combustibles.

For service access.

Locate appliance away from traffi c areas.

A. Select Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (See Figure 3.1).

Note: For actual appliance dimensions refer to Section 13.

Note: If this surface is inside the building’s warm air envelope...

B

AF

E

...then this surface must be an exterior wall system.

G

F

C

D

 

A

B

C

D

E

F

G

in.

24-3/4

24-1/8

48

49

5/8

1/2

1-1/2

 

 

 

 

 

 

 

 

mm

629

613

1219

1245

16

13

38

Figure 3.1 Appliance Locations

6

Heat-N-Glo Lifestyle Collection • Dakota 42/Dakota 42H • 4036-905 Rev I • 10/05

Page 6