Heat & Glo LifeStyle EM-415H, EM-485T TS345/TS345P Square Termination Cap, TCT375 Terra Cotta Cap

Models: EM-415H EM-415 EM-485TH EM-485T

1 52
Download 52 pages 54.84 Kb
Page 34
Image 34
•TS345/TS345P Square Termination Cap

TS345/TS345P Square Termination Cap

European Copper Series Termination Cap

Cap top comes assembled in place.

Termination Cap

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Chimney

Pipe

Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.

3 in. (76 mm)

Maximum

top of chase to top of

chimney section

Chase

Cap Top •European Copper Series Termination Cap

(Be sure holes •TCT375 Terra Cotta Cap in cap top and

cap base are aligned.)

Cap Base Manual background

Manual backgroundManual background brass screw (8)

(9 for the King-Style)

bolt (8)*

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).

Figure 9.7 Installing a TS345/TS345P Square Termination Cap

TCT375 Terra Cotta Cap

bracket (8)* Manual background screw (8)*

chase Manual background top

(metal or masonry)

Manual backgroundManual background nut (8)* Manual backgroundwasher (8)*

2 in. (51 mm) typical collar height

Place waterproof sealer under each flange of the termina- tion cap and on top of each screw to help prevent leaks.

CT-3A Adapter

SL pipe

14-1/2 in.

(368 mm)

Collar

2 in. (51 mm)

Minimum Height

Chase Top

Termination Cap

The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase

2 in. (51 mm)

7 in. (178 mm)

Chase

Chimney

Pipe

Figure 9.9 Installing an Adapter for European Copper Cap Se- ries (CT-King shown)

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Figure 9.8 Installing a TCT375 Terra Cotta Cap

34

Heat & Glo • EM-415, EM-485 • 33056 • Rev V • 05/08

Page 34
Image 34
Heat & Glo LifeStyle EM-415H, EM-485TH TS345/TS345P Square Termination Cap, European Copper Series Termination Cap