B. Clearances

B. Clearances

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specified in Fig- ure 6.2. DO NOT pack required air spaces with insulation or other materials.

Storm Collar

Roof Flashing

(attic)

(insulation)

2 in. (51 mm) min. Manual backgroundManual background

Shaded areas

represent

Manual background 2 in. (51 mm) min. air space clearance required around pipe

Attic

Insulation

Shield

(ceiling)

Offset/Return (secured

with hanger straps)

(ceiling)

Ceiling FirestopManual background

Adapter attached here

(not shown)

Object

 

 

Combustible

48 in.

 

 

 

 

1219 mm

0 in.

 

 

 

 

to floor

Must have 2 in. (51 mm)

minimum clearance

to header

Manual background 0 in. to level of standoffs

Manual background 3/4 in. (19 mm) to back & sides of appliance

(except at nailing flanges where it is 1/2 in. [13 mm])

Figure 3.2 Clearances to Combustible Materials

Note: Chimney air kit not shown, but required in Canada.

18

Heat & Glo • EM-415, EM-485 • 33056 • Rev V • 05/08

Page 18
Image 18
Heat & Glo LifeStyle EM-415H, EM-485TH owner manual B. Clearances