Heat & Glo LifeStyle EVEREST manual B. Installing Vent Components, Vertical Baffle

Models: EVEREST

1 27
Download 27 pages 12.36 Kb
Page 15
Image 15
B. Installing Vent Components

B. Installing Vent Components

If your vertical vent component is over 10 feet, you may want to install the included vertical baffle to improve flame appearance. Vertical baffle is located in the bag containing the instruction manual. Center the vertical baffle on the five inch flue being used, and with self tapping screws secure the baffle to the inside of the firebox (see Figure 10).

With vent runs of 30 feet or more without elbows, an additional baffle (SRV750-152) is to be used with the supplied baffle. This is a service part and is to be purchased separately.

 

VERTICAL

 

 

BAFFLE

5” EXHAUST

 

 

PIPE

Figure 10.

Vertical Baffle

 

1.Attach the First Vent Component to the Starting Collars

To attach the first vent component to the starting collars of the fireplace:

Make sure that the fireplace gasket supplied with the fireplace seals between the first component and the out- er fireplace wrap.

Refer to Cinch Pipe and Termination Cap installation in- structions.

2.Assembling Vent Sections

Refer to Cinch Pipe and Termination Cap installation in- structions.

!WARNING: ENSURE THAT THE FIBERGLASS GASKET SUPPLIED WITH THE FIREPLACE

SEALS BETWEEN THE FIRST VENT COMPONENT AND THE OUTER FIREPLACE WRAP.

If the installation is for a termination cap attached directly to the fireplace, skip to the sections, Install Firestops and Vent Termination.

Heat & Glo • Everest • 750-900 Rev. L • 1/06

15

Page 15
Image 15
Heat & Glo LifeStyle EVEREST manual B. Installing Vent Components, Vertical Baffle, Assembling Vent Sections