Step 4. Positioning, Leveling, and Securing the Fireplace
The diagram below shows how to properly position, level, and secure the fireplace.
NAILING TABS (BOTH SIDES)
Figure 20. Proper Positioning, Leveling, and
Securing of a Fireplace
1.Place the fireplace into position.
2.Level the fireplace from side to side and from front to back.
3.Shim the fireplace with
4.Secure the fireplace to the framing by nailing or screwing.
Step 5. The Gas Control Systems
WARNING: THIS UNIT IS NOT FOR USE WITH ! SOLID FUEL.
Intermittent Pilot Ignition (IPI) System
The gas control system used with this model is Intermittent Pilot Ignition (IPI). This system includes a 3V control valve, electronic module, and intermittent pilot.
!WARNING: CONTINUOUS 110-120 VAC SER-
VICE MUST BE WIRED TO THE FIREPLACE JUNCTION BOX.
!WARNING: DIRECT VENT PROPANE MODELS WITH IPI CONTROL SYSTEMS CANNOT BE USED IN CANADA.
Figure 21. Intermittent Pilot Ignition |
Heat & Glo • Everest • | 21 |