Heat & Glo LifeStyle Heat & Glo Gas Appliance, Dakota 42-B Framing and Clearances, Fire Risk

Models: Dakota 42-B Heat & Glo Gas Appliance Dakota 42H-B

1 36
Download 36 pages 6.52 Kb
Page 6
Image 6
3 Framing and Clearances

3 Framing and Clearances

Note:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

A. Select Appliance Location

When selecting a location for your appliance it is important to consider the required clearances to walls (See Figure 3.1).

A. Select Appliance Location WARNING

Fire Risk

Provide adequate clearance:

Around air openings.

To combustibles.

For service access.

Locate appliance away from traffic areas.

Note: For actual appliance dimensions refer to Section 13.

Note: If this surface is inside the building’s warm air envelope...

...then this surface must be an exterior wall system.

G

57-3/4 in.

 

B

 

(1467 mm)

A

 

G

F

F

 

F

 

 

 

 

E

C

 

 

 

D

81-3/4 in.

C(2076 mm)

D

Fire Risk E

Figure 3.1 Appliance Locations

 

A

B

C

D

E

F

G

in.

24-3/4

24-1/8

48

49

5/8

1/2

1-1/2

mm

629

613

1219

1245

16

13

38

Manual background WARNING

Fire Risk

Odor Risk

Install appliance on hard metal or wood surfaces extending full width and depth of appliance.

Do NOT install appliance directly on carpeting, vinyl, tile or any combustible material other than wood.

Manual background WARNING

Fire Risk

Locate and install appliance to all clearance specifications in manual.

6

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 Rev C • 07/06

Page 6
Image 6
Heat & Glo LifeStyle Heat & Glo Gas Appliance, Dakota 42-B Framing and Clearances, A. Select Appliance Location, Fire Risk