Heat & Glo LifeStyle ST-42TVFL-IPI owner manual For Intermittent Pilot Ignition IPI Wiring

Models: ST-42TVFL-IPI

1 27
Download 27 pages 62.54 Kb
Page 20
Image 20
*Shown with optional remote control receiver.

JUNCTION BOX

INTERMITTENT

PILOT IGNITOR

IGNITION

MODULE 3 VAC

I

S

TRANSFORMER 3V

BATTERY PACK

BLACK

RED

HI LIMIT SENSOR

REMOTE

RECEIVER

BROWN

BROWN

WHITE

ORANGE

GROUND TO FIREPLACE CHASSIS

ORANGE

GREEN

VALVE

PIGTAIL

CONNECTOR

*Shown with optional remote control receiver.

Figure 10. Intermittent Pilot Ignition (IPI) Wiring Diagram

For Intermittent Pilot Ignition (IPI) Wiring

Appliance Requirements

This appliance requires that 110-120 VAC be wired to the junction box. Maintain correct polarity when wiring the junction box.

Operation using Battery Power

This fireplace has an optional battery operation. The system is fully functional with the use of two “D” size batteries without ordinary 110-120 VAC power.

Wiring to the battery pack should be left disconnected in order to conserve battery life. In the case of a loss of power, simply connect red and black wire leads to activate battery power (connect red to red, black to black). The fireplace can be used as necessary. Once power (110 VAC) is restored, disconnect red and black wire leads to extend battery life.

20

Heat & Glo • ST-42TVFL-IPI455-902 Rev. C • 12/07

Page 20
Image 20
Heat & Glo LifeStyle ST-42TVFL-IPI owner manual For Intermittent Pilot Ignition IPI Wiring, Appliance Requirements