Maintenance

Fireplace

 

Although the frequency fireplace servicing and

Maintenance

maintenance will depend on use and the type of

 

 

 

 

installation, you should have a qualified service technician

 

 

 

 

perform an appliance check-up at the beginning of each

 

 

 

 

heating season. See the table below for specific

 

 

 

 

guidelines regarding each fireplace maintenance task.

IMPORTANT

 

TURN OFF THE GAS BEFORE SERVICING

 

 

 

 

YOUR FIREPLACE.

 

Type of

 

 

 

 

Fireplace Maintenance Task To

 

Maintenance

 

Frequency

 

By

Be Completed

 

 

 

 

 

 

 

 

Replacing

 

Once annually,

 

Qualified

Brush away loose ember material near

 

Old Ember

 

during the

 

Service

the burner. Replace old ember

 

Material

 

annual check-up

Technician

material with new dime-size and -shape

 

 

 

 

 

 

pieces of Golden Ember (GE-93) and

 

 

 

 

 

 

Glowing Ember (050-721). New ember

 

 

 

 

 

 

material should be placed alternately on

 

 

 

 

 

 

top of the burner—a layer of Golden

 

 

 

 

 

 

Ember, a layer of Glowing Ember,

 

 

 

 

 

 

and so on. Save the remaining ember

 

 

 

 

 

 

material and repeat this procedure at

 

 

 

 

 

 

your next servicing.

 

 

 

 

 

 

 

 

Cleaning

 

Once annually

 

Qualified

Brush or vacuum the control

 

Burner

 

 

 

Service

compartment, fireplace logs, and

 

& Controls

 

 

 

Technician

burner areas surrounding the logs.

 

 

 

 

 

 

 

 

Cleaning

 

Periodically

 

Qualified

Make a visual check of the straight flame

 

Flame Sensor

 

 

 

Service

sensor rod. Use emery cloth to carefully

 

Rod (IPI)

 

 

 

Technician

remove any existing film or white deposits.

 

System

 

 

 

 

 

 

 

 

 

 

 

 

 

Checking

 

Periodically

 

Qualified

Make a visual check of your fireplace’s

 

Flame

 

 

 

Service

flame patterns. Make sure the flames

 

Patterns,

 

 

 

Technician/

are steady—not lifting or floating. See

 

Flame Height

 

 

 

Owner

the picture in Figure 14. The flame

 

 

 

 

 

 

sensor or thermopile/thermocouple

 

 

 

 

 

 

tips should be covered with flame.

 

 

 

 

 

 

 

Checking

 

Before initial use

Qualified

Inspect the external vent cap on a

 

Vent System

 

and at least

 

Service

regular basis to ensure that no debris is

 

 

 

annually thereafter,

Technician/

interfering with the flow of air. Inspect

 

 

 

more frequently

Owner

entire vent system for proper function.

 

 

 

if possible

 

 

 

 

 

 

 

 

 

 

 

Cleaning

 

As necessary

 

Homeowner

Remove and clean glass after the first 3-4

 

 

 

 

 

 

hours of use. After the initial cleaning, clean

 

 

 

 

 

 

as necessary, particularly after adding new

 

 

 

 

 

 

ember (flame colorant) material. Film deposits

 

 

 

 

 

 

on inside of glass door should be cleaned

 

 

 

 

 

 

off using a household glass cleaner. NOTE:

 

 

 

 

 

 

DO NOT handle or attempt to clean door

 

 

 

 

 

 

whenit’shot.DONOTuseabrasivecleaners.

 

 

 

 

 

 

 

4

Maintaining and Servicing Your Fireplace

SHUTTER SETTINGS

 

NG

1/2 INCH

 

 

 

 

LP

FIXED

 

 

 

MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOATING.

Figure 15.

Burner Flame Patterns

26

Heat & Glo • ST-42TVFL-IPI455-902 Rev. C • 12/07