Heat & Glo LifeStyle ST-42TVFL-IPI Step Gas Pressure Requirements, Gas Supply Line, Natural Gas

Models: ST-42TVFL-IPI

1 27
Download 27 pages 62.54 Kb
Page 18
Image 18
Step 8

18

The gas line should be installed by a qualified service technician.

Step 8

Gas Pressure

Requirements

At the gas line access hole, use insulation to re- pack the space around the gas pipe.

Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.

 

USE A WRENCH ON

 

SHUT-OFF VALVE

 

WHEN TIGHTENING

 

GAS LINE

 

MANUAL

 

SHUT-OFF

 

VALVE

GAS LINE

GAS VALVE

 

ACCESS

FLEX

 

CONNECTOR

Figure 9. Gas Supply Line

Pressure requirements for Heat & Glo gas fireplaces are shown in the table below.

Pressure

Natural Gas

Propane

 

 

 

Minimum

5.0 inches

11.0 inches

Inlet Pressure

w.c.

w.c.

 

 

 

Maximum Inlet

14.0 inches

14.0 inches

Gas Pressure

w.c.

w.c.

 

 

 

Manifold

3.5 inches

10.0 inches

Pressure

w.c.

w.c.

A one-eighth (1/8) inch (3 mm) N.P.T. plugged tapping is provided on the inlet and outlet side of the gas control for a test gauge connection to measure the manifold pressure.

The fireplace and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of one-half (1/2) psig (3.5 kPa).

The fireplace must be isolated from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than one- half (1/2) psig (3.5 kPa).

Heat & Glo • ST-42TVFL-IPI455-902 Rev. C • 12/07

Page 18
Image 18
Heat & Glo LifeStyle ST-42TVFL-IPI owner manual Step Gas Pressure Requirements, Gas Supply Line, Natural Gas, Propane