18
The gas line should be installed by a qualified service technician.
Step 8
Gas Pressure
Requirements
•At the gas line access hole, use insulation to re- pack the space around the gas pipe.
•Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
| USE A WRENCH ON |
| |
| WHEN TIGHTENING |
| GAS LINE |
| MANUAL |
| |
| VALVE |
GAS LINE | GAS VALVE |
| |
ACCESS | FLEX |
| CONNECTOR |
Figure 9. Gas Supply Line
Pressure requirements for Heat & Glo gas fireplaces are shown in the table below.
Pressure | Natural Gas | Propane |
|
|
|
Minimum | 5.0 inches | 11.0 inches |
Inlet Pressure | w.c. | w.c. |
|
|
|
Maximum Inlet | 14.0 inches | 14.0 inches |
Gas Pressure | w.c. | w.c. |
|
|
|
Manifold | 3.5 inches | 10.0 inches |
Pressure | w.c. | w.c. |
A
The fireplace and its individual
The fireplace must be isolated from the gas supply piping system by closing its individual
Heat & Glo •