F. Installing Adaptor and Termination Cap

F. Installing Adaptor and Termination Cap

For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.5) .

To install adaptor see Figure 8.6.

HORIZONTAL

OVERHANG

CAUTION! Risk of Cuts/Abrasions/Flying Debris.

Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Damper Flashing Kit (Optional)

For use with LINK-DV30B or LINK-DV4-30B Liner Kit. Note: Damper may have to be removed to use this kit.

Run flex liners through 3 in. holes in damper flashing.

Attach damper flashing to firebox roof with self tapping

2FT.

MIN.

GAS DIRECT VENT

TERMINATION CAP

20 INCHES MIN.

VERTICAL

LOWEST

WALL

 

DISCHARGE

 

OPENING

 

X

12

Masonry ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

screws included in kit.

CLASS A PIPE

Roof Pitch

H (Min.) Ft.

Flat to 6/12

....................

1.0*

Over 6/12 to 7/12

1.25*

Over 7/12 to 8/12

1.5*

Over 8/12 to 9/12

2.0*

Over 9/12 to 10/12

2.5*

Over 10/12 to 11/12

3.25

Roof Pitch

H (Min.) Ft.

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

Figure 8.6

* 3 foot minimum in snow regions

Figure 8.5 Minimum Height from Roof to Lowest Discharge Opening

To prevent odors and cold drafts, the chimney must be sealed around the vent with non-combustible blanket insulation or field fabricated metal plates.

Note: The LINK-DV4-30B

system REQUIRES this insulation.

Masonry

 

Factory Built

LINK-DV30B

LINK-DV4-30B

Installation

Installation

Wood Burning

 

 

TERMINATION

 

 

OPTIONAL LINK-ZC-ADPB

 

 

CAP

 

 

 

FOR USE WITH CLASS A

 

EXHAUST

 

 

EXHAUST

 

WOODBURNING PIPE

 

AIR

 

 

AIR

 

 

 

VENT PIPE

 

 

VENT PIPE

 

 

 

 

OR

WARNING:

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT BLOCK

 

 

 

 

 

 

THIS PIPE END!

 

 

 

 

 

 

Note: Untwist the

 

 

 

 

 

 

pipe while extend-

 

 

 

 

 

 

ing it, to achieve full

 

 

 

 

 

 

30’ length.

 

 

 

INLET AIR

 

 

INLET AIR

Remove 18 inch x 18 inch flashing on cap by removing 3

 

 

 

VENT PIPE

 

VENT PIPE

 

 

screws. Connect both the LINK-ZC-ADPB to Class A Pipe

 

 

 

 

Figure 8.7

 

 

 

 

and the termination cap to the LINK-ZC-ADPB with the

 

 

 

 

self tapping screws provided.

 

24