5.Module Reset

4.If you intend to use both an optional wired wall switch and the RC300 remote control to operate your fireplace, the wall switch will override any commands given by the remote.

 

SELECTOR

 

SWITCH

STATUS INDICATOR LED

FLAME HI/LO SWITCH

NG/LP SETTING

Figure 2.3 Control Module

5.Module Reset

This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying a RED/GREEN error code at its status indicator LED.

Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section G.

Locate the module selector switch. (See Figure 2.3).

Set the module selector switch to the OFF position.

Wait five (5) minutes to allow possible accumulated gas to clear.

Set the module selector switch to ON or REMOTE position.

Start the appliance.

WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.

Nine Hour Safety Shutdown Feature

This appliance will automatically shut down after nine hours of continuous operation.

NOTICE: If the appliance shuts down after 9 hours of continuous operation, the module must be reset. See Module Reset instructions in this section.

I. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/ or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper- ate fireplace with fixed glass assembly removed.

Determine if this fireplace has a standing pilot or an Intellifire ignition system. Ask your dealer or open control access panel, look at gas valve.

A standing pilot ignition will have a red or black ignitor button (refer to Figure 2.4).

An Intellifire ignition system will not have a button.

RED OR BLACK IGNITOR BUTTON

Figure 2.4 Ignitor Button

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11