C. Clear Space
WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2.
Avoid placing candles and other
|
|
| APPLIANCE INSTALLED IN EXISTING |
|
|
| SOLID FUEL FIREPLACE |
| 3 | FT. | CLEAR |
|
| ||
|
| IN | |
|
|
| FRONT OFSPACE |
|
|
| FIREPLACE |
Figure 2.2 | Clear Space |
|
D. Decorative Doors, Fronts and Surrounds
WARNING! Risk of Fire! Install ONLY doors, fronts or surrounds approved by Hearth & Home Technologies. Unapproved doors or fronts may cause appliance to over- heat.
This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.
For more information refer to the instructions supplied with your decorative door or front.
E. Fixed Glass Assembly
See Section 12.H.
F.Remote Controls, Wall Controls and Wall Switches
Follow the instructions supplied with the control installed to operate your fireplace:
For safety:
•Install a switch lock or a wall/remote control with child protection lockout feature.
•Keep remote controls out of reach of children.
See your dealer if you have questions.
G. IPI Battery Tray/Battery Installation
The IntelliFire PlusTM system has a battery backup option. Battery longevity and performance will be affected by the service temperatures of this appliance.
NOTICE: Batteries should only be used as a power source in the event of an emergency such as an outage.
H. Control Module Operation
1.The control module has an ON/OFF/REMOTE selector switch that must be set. See Figure 2.3.
OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall switch or remote. The unit should be in the OFF position during installation, service, battery installation, fuel conversion, and in the event that the control goes into
ON Position: Appliance will ignite and run continuously in the HI flame setting, with no adjustment in flame output. This mode of operation is primarily used for initial installation or power outage operation with battery backup.
REMOTE Position: Appliance will initiate commands from an optional wired wall switch and/or the wireless remote (RC300).
2.If using a wired wall switch with the module in REMOTE mode, the flame output can be adjusted with the HI/LO selector switch on the module. See Figure 2.3. Note that the flame HI/LO selector switch will become inactive once an optional remote control (RC200/RC300) is programmed to the control module. Note that the control module will always ignite the fireplace on HI and remain so for the initial 10 seconds of operation. If the HI/LO is switched to the LO position, the flame output will automatically drop to the lowest setting after the flame has been established for 10 sec. After this 10 second period, the flame can be adjusted from HI to LO with the switch.
3.The control module has safety feature that automatically shuts down the fireplace after 9 hours of continuous operation without receiving a command from the RC300 remote.
8 | Heat & Glo • |