Heat Controller A-13 installation instructions Operating Instructions

Models: A-13

1 56
Download 56 pages 46.58 Kb
Page 20
Image 20
OPERATING INSTRUCTIONS

If the control detects the following failures, the LED will flash on for approximately 1/4 sec- ond, then off for 3/4 second for designated failure detections.

1 Flash: Failed to detect flame within the three tries for ignition.

2 Flash: Pressure switch or induced draft blower problem detected.

3 Flash: High limit or auxiliary limit open.

4 Flash: Flame sensed and gas valve not energized or flame sensed with no “W” signal.

5 Flash: Overtemperature switch open.

OPERATING INSTRUCTIONS

This appliance is equipped with integrated furnace control. This device lights the main burners each time the room thermostat (closes) calls for heat. See operating instructions on the back of the furnace/controls access panel.

!WARNING

DO NOT ATTEMPT TO MANUALLY LIGHT THIS FURNACE WITH A MATCH OR ANY OPEN FLAME. ATTEMPTING TO DO SO CAN CAUSE AN EXPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

TO START THE FURNACE

1.STOP! Read the safety information on the Operating Instructions label located on this appliance.

!WARNING

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

2.Set the thermostat to its lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance does not have a pilot. It is equipped with an ignition device which auto- matically lights the burner. Do NOT try to light the burner by hand.

5.Remove control door/access panel.

6.Move switch to the “OFF” position.

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions.

If you cannot reach your gas supplier, call the fire department.

If you don’t smell gas, go to the next step.

8.Move “OFF” position to “ON” position.

9.Replace the control door.

10.Turn on all electric power to the appliance.

11.Set the thermostat to the desired setting.

12.If the appliance will not operate, follow the instructions below on how to shut down the furnace.

!WARNING

THE SPARK IGNITOR AND IGNITION LEAD FROM THE IGNITION CONTROL ARE HIGH VOLTAGE. KEEP HANDS OR TOOLS AWAY TO PREVENT ELECTRI- CAL SHOCK. SHUT OFF ELECTRICAL POWER BEFORE SERVICING ANY OF THE CONTROLS. FAILURE TO ADHERE TO THIS WARNING CAN RESULT IN PERSONAL INJURY OR DEATH.

The initial start-up on a new installation may require the control system to be energized for some time until air has bled through the system and fuel gas is available at the burners.

TO SHUT DOWN FURNACE

1.Set the thermostat to the lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Remove control door.

4.Move switch to the “OFF” position.

5.Replace control door.

20

Page 20
Image 20
Heat Controller A-13 installation instructions Operating Instructions