A-13 installation instructions TON COOLING - 13 SEER, System Charge Charts
Models:
A-13
1
49
56
56
Download
56 pages
46.58 Kb
46
47
48
49
50
51
52
53
<
>
Troubleshooting
Specs
Install
Wiring Diagram
Warranty
Dimension
Maintenance
Ix. Wiring
Symptom
Manual Reset Overtemperature Control
Page 49
Image 49
FIGURE 32
SYSTEM CHARGE CHARTS
4 TON COOLING - 13 SEER
49
Page 48
Page 50
Page 49
Image 49
Page 48
Page 50
Contents
HEAT CONTROLLER
INSTALLATION INSTRUCTIONS
e f r i g e r a n t
D. Cover Panel Installation/Conversion Procedure
I.TABLE OF CONTENTS
D. Adjusting or Checking Furnace Input
C. Attaching Exhaust and Combustion Air Inlet Hoods
1. Specification of R-410A
IV. SPECIFICATIONS
II. INTRODUCTION
III. CHECKING PRODUCT RECEIVED
4. Tools Required For Installing & Servicing R-410A Models
V. SAFETY INFORMATION
2. Quick Reference Guide For R-410A
3. Evaporator Coil / TXV
CABINET DIMENSIONS AND ACCESS LOCATIONS
VI. UNIT DIMENSIONS
FOR CLEARANCES SEE FIGURE
BOTTOM VIEW
CABINET DIMENSIONS AND ACCESS LOCATIONS
SUPPLY AND RETURN DIMENSIONS
I282
I288
A. GENERAL
VII. INSTALLATION
B. OUTSIDE SLAB INSTALLATION
C. ATTACHING EXHAUST AND COMBUSTION AIR INLET HOODS
D. COVER PANEL INSTALLATION/CONVERSION PROCEDURE
E. CLEARANCES
G. DUCTWORK
F. ROOFTOP INSTALLATION
H. RETURN AIR
NAILER STRIP
ROOFTOP UNI
INSULATION
CANTSTRIP
A. GAS CONNECTION
VIII. GAS SUPPLY, CONDENSATE DRAIN AND PIPING
C. NOx MODELS
B. LP CONVERSION
D. ADJUSTING OR CHECKING FURNACE INPUT
A. POWER SUPPLY
IX. WIRING
E.CONDENSATE DRAIN
WARRANTY MAY BE JEOPARDIZED IF ALUMINUM WIRE IS CONNECTED TO
BRANCH CIRCUIT AMPACITY SUPPLY WIRE LENGTH-FEET
Taken from National Electric Code
IMPORTANT THIS UNIT IS APPROVED FOR USE WITH COPPER CONDUCTORS
B. HOOK-UP
C. INTERNAL WIRING
D. THERMOSTAT
NORMAL FURNACE OPERATING SEQUENCE
X. FURNACE SECTION CONTROLS AND IGNITION SYSTEM
OPERATING INSTRUCTIONS
PRESSURE SWITCH
MANUAL RESET OVERTEMPERATURE CONTROL
XI. SYSTEM OPERATING INFORMATION
BURNERS
FURNACE SECTION MAINTENANCE
LUBRICATION
COOLING SECTION MAINTENANCE
TROUBLESHOOTING
REPLACEMENT PARTS
WIRING DIAGRAMS
CHARGING
SPEED TAP BLOCK
INTEGRATED FURNACE CONTROL
FIGURE 22 Continued
NOMINAL SIZES 3-5 TONS 10.6-17.6 kW
XII. GENERAL DATA - TGC MODELS
Continued
NOMINAL SIZES 3-5 TONS 10.6-17.6 kW
GENERAL DATA - TGC MODELS
Continued
NOMINAL SIZES 3-5 TONS 10.6-17.6 kW
GENERAL DATA - TGC MODELS
Continued
NOMINAL SIZES 3-5 TONS 10.6-17.6 kW
GENERAL DATA - TGC MODELS
Continued
NOMINAL SIZES 3-5 TONS 10.6-17.6 kW
GENERAL DATA - TGC MODELS
ELECTRICAL DATA - TGC SERIES
XIII. MISCELLANEOUS
ELECTRICAL DATA - TGC SERIES
Information
GAS ELECTRIC UNITS - TGC
DRIVE
INDOOR AIRFLOW PERFORMANCE FOR
TON PACKAGE
DRIVE
INDOOR AIRFLOW
DIRECT-DRIVE 230 AIRFLOW PERFORMANCE
GAS ELECTRIC UNITS - TGC
DRIVE
INDOOR AIRFLOW PERFORMANCE FOR
TON PACKAGE
3 TON - 13 SEER MODELS
GAS ELECTRIC UNITS - TGC
INDOOR AIRFLOW PERFORMANCE FOR 3-5 TON PACKAGE
COMPONENT AIR RESISTANCE
NOTE Factory sheave settings are shown in bold print
3.5 TON - 13 SEER MODELS
GAS ELECTRIC UNITS - TGC
INDOOR AIRFLOW PERFORMANCE FOR 3-5 TON PACKAGE
NOTE Factory sheave settings are shown in bold print
4 TON - 13 SEER MODELS
COMPONENT AIR RESISTANCE
NOTE Bold lines separate L, M and N drives respectively
NOTE Factory sheave settings are shown in bold print
5 TON - 13 SEER MODELS
COMPONENT AIR RESISTANCE
BELT
WIRING DIAGRAM
WIRING DIAGRAM
WIRING DIAGRAM
WIRING DIAGRAM
WIRING DIAGRAM
WIRING DIAGRAM
WIRING DIAGRAM
SYSTEM CHARGE CHARTS
3 TON COOLING - 13 SEER
92-102259-01-01
SYSTEM CHARGE CHARTS
3.5 TON COOLING - 13 SEER
SYSTEM CHARGE CHARTS
4 TON COOLING - 13 SEER
5 TON COOLING - 14 SEER
SYSTEM CHARGE CHART - REFRIGERANT 410A
5 TON, 14 SEER
POSSIBLE CAUSE
SYMPTOM
REMEDY
COOLING TROUBLE SHOOTING CHART
FURNACE TROUBLESHOOTING GUIDE
COMBINATION HEATING AND COOLING UNITS WITH DIRECT SPARK IGNITION
HAZARDOUS VOLTAGE
Page
Page