Electrical Requirements

Heat Controller, Inc.

Room Air Heat Pump with R-410A

Owner’s Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window installation

Window opening measurements:

27" min. to 39" max. opening width.

16¹⁄₄" min. opening height.

A

B

A. 27" min.

B. 16¹⁄₄" min.

Through-the-wall installation

The wall opening measurements should be:

Height: 16" plus twice the thickness of wood used to build frame.

Width: 22⁵⁄₈" plus twice the thickness of wood used to build frame.

Electrical Shock HazardDo not use an adapter. C

A

B Do not use an extension cord.

C

A.16"

B. 22⁵⁄₈"

C. Wood thickness

Electrical Requirements

Power supplyWARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

Ground wire must be connected to ground screw located in lower right corner of air conditioner when air conditioner is in cabinet.

The electrical ratings for your air conditioner are listed on the model and serial number label. The model and serial number label is located behind the front panel on the flange below the control panel area.

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power supply

 

 

cord
Wiring requirements

 

 

115-volt (103.5 min. - 126.5 max.)

 

 

0-12 amps

 

 

15-amp time-delay fuse or circuit breaker

 

 

Use on single outlet circuit only.

 

 

 

¹⁄₄"

230-volt (207 min. - 253 max.)

 

0-12 amps

(0.6 cm)

 

 

15-amp time-delay fuse or circuit breaker

 

 

 

 

 

 

Use on single outlet circuit only.

 

 

 

 

 

 

208/230-volt (198min. - 253 max.)

 

 

0-16 amps

 

 

20-amp time-delay fuse or circuit breaker

 

 

Use on single outlet circuit only.

 

 

 

¹⁄₂"

230-volt (207 min. - 253 max.)

 

0-24 amps

(1.3 cm)

30-amp time-delay fuse or circuit breaker Use on single outlet circuit only.