Motion Sensing Halogen Fixture
OPERATION
Mode: | Works: Day | Night | |
|
|
|
|
Test | 5 Sec | x | x |
Auto | 1, 5, 10 min. |
| x |
Manual | Until Dawn* |
| x |
|
|
|
|
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.
Model SL-5525
Features
¥ Turns on lighting when motion is detected. |
¥ Automatically turns lighting off. |
TEST
Put the
ON-TIME
10 5 1 TEST
¥ Photocell keeps the lighting off during daylight hours. |
¥ LED indicates motion was sensed (day or night). |
This package includes:
Plastic Hanger
AUTO
Put the
MANUAL MODE
10 5 1 TEST
6 Screws | Gasket |
(3 sizes included) | |
| 1 Halogen |
| Lamp |
| Sensor |
3 Wire |
|
Connectors | Mounting Strap Light Control |
|
Manual mode only works at night because daylight returns the sen- sor to AUTO.
Flip the light switch off for one sec- ond then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the
1 Second OFF
then...
... back on.
Mounting Bolt
Rubber Plug
Light Shield
Requirements
¥The Light Control requires
¥If you want to use Manual Mode, the control must be wired through a switch.
•Some codes require installation by a qualified electrician.
¥This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
Mode Switch Summary
| TEST |
|
| Move | ||||
| ||||||||
|
|
|
|
|
|
| 1, 5, or 10 minutes | |
|
|
|
|
|
|
| ||
| AUTO |
|
|
|
|
| Flip light switch off | |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| for one second |
|
|
|
|
|
|
|
| then back on* |
MANUAL MODE |
|
|
| |||||
|
|
|
| |||||
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
© 2004 DESA Specialty Productsª |