B. Design and Installation Considerations
Heatilator direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required.
Installation MUST comply with local, regional, state and national codes and regulations. Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.
Before installing, determine the following:
•Where the appliance is to be installed.
•The vent system configuration to be used.
•Gas supply piping.
•Electrical wiring requirements.
•Framing and finishing details.
•Whether optional
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified service technician, service agency or your dealer.
C.Tools and Supplies Needed
Before beginning the installation be sure that the following tools and building supplies are available.
Tape measure | Framing material |
Pliers | |
Hammer | Phillips screwdriver |
Gloves | Framing square |
Voltmeter | Electric drill and bits (1/4 in.) |
Plumb line | Safety glasses |
Level | Reciprocating saw |
Manometer | Flat blade screwdriver |
1/2 - 3/4 in. length, #6 or #8
Caulking material (300ºF minimum continuous exposure rating)
D. Inspect Appliance and Components
•Carefully remove the appliance and components from the packaging.
•The vent system components and decorative doors and fronts may be shipped in separate packages.
•If packaged separately, the log set and appliance grate must be installed.
•Report to your dealer any parts damaged in shipment, particularly the condition of the glass.
•Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.
WARNING! Risk of Fire or Explosion! Damaged parts could impair safe operation. DO NOT install damaged, in- complete or substitute components. Keep appliance dry.
Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:
•Installation and use of any damaged appliance or vent system component.
•Modification of the appliance or vent system.
•Installation other than as instructed by Hearth & Home Technologies.
•Improper positioning of the gas logs or the glass door.
•Installation and/or use of any component part not approved by Hearth & Home Technologies.
Any such action may cause a fire hazard.
WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water.
Heatilator • GDST3831I • | 17 |