B. Vent Components Diagrams (continued)

HORIZONTAL TERMINATION CAP WARNING

Fire Risk.

When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fireplaces, a one foot minimum vertical vent section is

required before installing first elbow.

When using DVP-TB1 termination cap on top vented fireplaces, a three foot minimum vertical ventsectionisrequired before installing first elbow.

15in.

(381 mm)

8-1/8 in.

(206 mm)

13in.

(330 mm)

Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm

5-1/2 in.

8-3/8 in.

140 mm

213 mm

87° DVP-TB1Manual backgroundManual background

Manual backgroundManual background 10-1/2 in.

267 mm

10-7/8 in. 276 mm

Manual background SLP-HRC-SS SLP-HRC-ZC-SS

HORIZONTAL TERMINATION CAP

DVP-TB1

SLP90 SL-2DVP

ASSEMBLY

DVP-TB1

DVP-TB1

HORIZONTAL TERMINATION CAP

Figure 16.5 SLP Series Vent Components

58