Fun~tio~

 

el 520

ke

Fun~tio~

High Temperature

The high temperature thermostat is a manual reset control

Control

which sensesthe temperature of the shortening. If the shorten-

 

ing temperature exceeds the safe operating limit, this control

 

will remove power from the contactors, thus removing heat

 

to the cook pot. When the temperature of the shortening drops

 

to preset safe operating limit, the control must be manually

 

reset. The reset button is located on the upper surface of the

 

recess in the front panel below the regulating thermostat.

Lid/Locking Assembly

15 Condensate Drain Pan

Before pressure will build in the cook pot, the lid must be closed and locked. To close the lid, push the lid down with one hand by using the plastic handle on top of the lid. While holding the lid closed with one hand,. turn the handle on the latch counterclockwise 160o(until it contacts the stop) to lock the lid.

DO NOT place your free hand on top of the lid during the latching procedure. The surface may be hot and burns could result.

The lid will not latch or pressure build unless the handle is fully latched. As pressure builds within the cook pot, the handle will be locked in place. As long as the locking assembly is engaged, it will prevent the handle from being moved clockwise and opening the lid. The locking assembly disengages when the internal pressure falls below 1 PSI (6.8 KPa).

The condensate drain pan is located behind the panel, below the drain and filter valve handles. Remove the panel and the condensate pan is located on the left. It can be easily removed by grasping the handle and pulling out carefully. The conden- sation pan should be emptied daily.