RS-232C communication (continued)

Names

Operation Type

Header

Command Data

CRC

Action

Type

Setting Code

COLOR TEMP

Set

HIGH

BE EF

03

06

00

0B F5

01

00

B0

30

03

00

 

 

CUSTOM-1 (HIGH)

BE EF

03

06

00

CB F8

01

00

B0

30

13

00

 

 

MID

BE EF

03

06

00

9B F4

01

00

B0

30

02

00

 

 

CUSTOM-2 (MID)

BE EF

03

06

00

5B F9

01

00

B0

30

12

00

 

 

LOW

BE EF

03

06

00

6B F4

01

00

B0

30

01

00

 

 

CUSTOM-3 (LOW)

BE EF

03

06

00

AB F9

01

00

B0

30

11

00

 

 

Hi-BRIGHT-1

BE EF

03

06

00

3B F2

01

00

B0

30

08

00

 

 

CUSTOM-4 (Hi-BRIGHT-1)

BE EF

03

06

00

FB FF

01

00

B0

30

18

00

 

 

Hi-BRIGHT-2

BE EF

03

06

00

AB F3

01

00

B0

30

09

00

 

 

CUSTOM-5 (Hi-BRIGHT-2)

BE EF

03

06

00

6B

FE

01

00

B0

30

19

00

 

 

Hi-BRIGHT-3

BE EF

03

06

00

5B F3

01

00

B0

30

0A 00

 

 

CUSTOM-6 (Hi-BRIGHT-3)

BE EF

03

06

00

9B

FE

01

00

B0

30

1A 00

 

 

Get

BE EF

03

06

00

C8 F5

02

00

B0

30

00

00

COLOR TEMP GAIN R

 

Get

BE EF

03

06

00

34

F4

02

00

B1

30

00

00

 

 

Increment

BE EF

03

06

00

52

F4

04

00

B1

30

00

00

 

 

Decrement

BE EF

03

06

00

83

F5

05

00

B1

30

00

00

COLOR TEMP GAIN R

 

Execute

BE EF

03

06

00

10 C6

06

00

46 70

00

00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP GAIN G

 

Get

BE EF

03

06

00

70

F4

02

00

B2

30

00

00

 

 

Increment

BE EF

03

06

00

16

F4

04

00

B2

30

00

00

 

 

Decrement

BE EF

03

06

00

C7 F5

05

00

B2

30

00

00

COLOR TEMP GAIN G

 

Execute

BE EF

03

06

00

EC C7

06

00

47 70

00

00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP GAIN B

 

Get

BE EF

03

06

00

8C F5

02

00

B3

30

00

00

 

 

Increment

BE EF

03

06

00

EA F5

04

00

B3

30

00

00

 

 

Decrement

BE EF

03

06

00

3B F4

05

00

B3

30

00

00

COLOR TEMP GAIN B

 

Execute

BE EF

03

06

00

F8 C4

06

00

48 70

00

00

Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP

 

Get

BE EF

03

06

00

04

F5

02

00

B5

30

00

00

OFFSET R

 

Increment

BE EF

03

06

00

62

F5

04

00

B5

30

00

00

 

 

Decrement

BE EF

03

06

00

B3 F4

05

00

B5

30

00

00

COLOR TEMP

 

Execute

BE EF

03

06

00

40 C5

06

00

4A

70

00

00

OFFSET R Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP

 

Get

BE EF

03

06

00

40

F5

02

00

B6

30

00

00

OFFSET G

 

Increment

BE EF

03

06

00

26

F5

04

00

B6

30

00

00

 

 

Decrement

BE EF

03

06

00

F7

F4

05

00

B6

30

00

00

COLOR TEMP

 

Execute

BE EF

03

06

00

BC C4

06

00

4B

70

00

00

OFFSET G Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR TEMP

 

Get

BE EF

03

06

00

BC F4

02

00

B7

30

00

00

OFFSET B

 

Increment

BE EF

03

06

00

DA F4

04

00

B7

30

00

00

 

 

Decrement

BE EF

03

06

00

0B F5

05

00

B7

30

00

00

COLOR TEMP

 

Execute

BE EF

03

06

00

C8

C5

06

00

4C

70

00

00

OFFSET B Reset

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 