English
Hold the handle tightly and push the battery latch (2
pcs.) to remove the battery (see Figs. 1 and 2).
CAUTIONNever
Before using the impact driver drill, charge the battery as follows.
1.Connect the charger’s power cord to a receptacle When the power cord is connected, the charger’s pilot lamp will blink in red (At
Firmly insert the battery into the charger till it contacts the bottom of the charger and checking the polarities
as shown in Fig. 3.
CAUTION
If the batteries are inserted in the reverse direction,
not only recharging will become impossible, but it may also cause problems in the charger such as a deformed recharging terminal.
3.ChargingWhen inserting a battery in the charger, charging will commence and the pilot lamp will light continuously in red.
When the battery becomes fully recharged, the pilot lamp will blink in red (At
(1)Pilot lamp indication
The indications of the pilot lamp will be as shown in Table 1, according to the condition of the charger or the rechargeable battery.
| Before | Blinks |
| charging | (RED) |
| While | Lights |
Charge status | charging | (RED) |
|
| |
lamp (RED) | Charging | Blinks |
| complete | (RED) |
| Charging | Flickers |
| impossible | (RED) |
Overheat lamp | Overheat | Lights |
standby | (GREEN) | |
(GREEN) |
|
|
|
|
|
Indications of the pilot lamp
Lights for 0.5 seconds. Does not light for 0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for 0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for 0.1 seconds. (off for 0.1 seconds)
Lights continuously
Malfunction in the battery or the charger.
Battery overheated. Unable to charge. (Charging will commence when battery cools)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
(2)Regarding the temperatures of the rechargeable battery
The temperatures for rechargeable batteries are as shown in Table 2, and batteries that have become hot should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
(3)Regarding recharging time
Depending on the combination of the charger and batteries, the charging time will become as shown in Table 3.
Table 3 Charging time (At 20°C)
Charger
Temperatures at which the
Rechargeable batteries battery can be recharged
Battery
UC18YRL
BCL1430, EBL1430, EBM1430
BCL1430, EBL1430, EBM1430, EBM1830
0°C – 50°C
EBM1830
NOTEApprox. 45 min.
The charging time may vary according to temperature and power source voltage.