Memory Function / Sensors / Auto Detection
Memory Function
When you stop the operation and then restart, the purifier will resume the operation status before shutdown. If you operate the purifier for approx. 5 seconds or longer, the operation status will be stored in memory. (If you stop the operation within less than 5 seconds, the operation status will not be stored in memory.) Even if you unplug the power cord, the operation status will be stored in memory. However, the airflow rate is automatically set to “Auto”.
Air Sensor
Level of air contamination detected by the odor sensor is shown by the way the indicator is activated.
Indicator action | : Lit in green | Blink in green |
Contamination level: Clean | Contaminated |
Note
You can adjust the air sensor sensitivity setting as desired. |
| |
|
In case the purifier is installed in a place where air contamination is hard to detect or in case the sensor itself
is not clean, the indicator action may not change. |
| |
|
Odor Sensor
The sensor detects odor in air such as cigarette smoke or odor of pet animals. Even when you feel the air is clean, the purifier may continue the operation if the odor sensor finds any gas component not removed by the filter.
Any of the following may also be detected by the odor sensor.
Combustion gas from heating appliance, alcohol, odor of perfumes or cosmetics used in beauty parlor or aesthetic salon, sprays, vapor, abrupt temperature change, etc.
Odor sensor
Humidity Sensor
The humidity sensor finds the humidity of room air during operation.
Humidity level should be taken as a guide only.
The indication may differ from hygrometer reading.
Humidity will change as temperature changes.
Humidity level may differ between
Humidity Sensor
Auto Detection
The air purifier performs automatic operation by detecting room air contamination with “Odor Sensor” and room air humidity with “Humidity Sensor”.
In the first 3 minutes after the power cord is plugged in, the unit will check room air condition and save it in memory. During the time, the “Air Sensor” indicator and “Humidity Level 50” indicator will blink. After 3 minutes, both the “Air Sensor” and “Humidity Level 50” indicators will go off and the purifier is now ready to operate.
You may start the operation in less than 3 minutes after plugging the power cord.
In this case too, the “Air Sensor” and “Humidity Level 50” indicators will continue to blink, meaning the unit is checking room air condition. After 3 minutes, the indicators will show your room air conditions.
If you plug in the power cord under contaminated air condition, the sensor sensitivity may be reduced. In such a case, perform High or Max operation. Or you may try to make the room air cleaner by opening a window before plugging the power cord. If the sensor sensitivity remains low after this, change the sensor sensitivity setting.