Viewing Alarm Messages

3.7. Viewing Alarm Messages

&

F

An alarm is given by steady light of the “alarm” lamp.

Pressing the “Reset” key erases the steady light of the “alarm” lamp (the “alarm” lamp goes off). The failure is not re- paired.

Failures must be repaired immediately.

Possible events:

- Fault hopper

In the operating mode “probe conveying”, the level of material has not rea- ched the probe within the set conveying time.

Possible causes: lack of material, false conveying time setting or defective probe. In the operating mode “time-controlled conveyance”, no signal change of the flap switch has occurred within the set emptying time.

Possible causes: lack of material, false emptying time setting or defective flap.

SM4-618

Start-up 3-8

Page 23
Image 23
Sterling SGFE operating instructions Viewing Alarm Messages, Possible events Fault hopper