Checking the direction of rotation of the vacuum generator

4.3. Checking the direction of rotation of the vacuum generator

Start a conveying procedure.

Wait until the vacuum generator begins to operate.

Observe the rotational direction arrow on the vacuum generator housing.

Stop the conveying procedure.

Wait until the blower has come to a standstill.

Switch off the unit.

If the vacuum generator rotates in the wrong direction, correct the direction by changing the poles of two phases.

»

F

Electrical connections should only be carried out by trained staff.

Observe the regulations of your local Electricity Board.

The wrong direction of rotation may lead to major defects or may interfere with the function of the vacuum generator.

A proper conveyance is not possible.