Sterling SGFE operating instructions Technical data

Models: SGFE

1 50
Download 50 pages 57.73 Kb
Page 43
Image 43

SGFE

7. Technical data

Version: 64.10-0198GB05TD 02/01

Method of filling: . . . . . . . . . . time conveying mode or probe conveying mode

. . . . . . . . . . . . . . . . . . . . . . . . . . with conveying time used as monitoring time

Vacuum generator (depending on the model)

Side vane vacuum pump GSV: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5-4.4 kW

Noise level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 75-78 dB(A)

Rotary valve pump GDS: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0-11.0 kW

Noise level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 73-75 dB(A)

Rotary lobe vacuum pump GDK: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0 kW

Noise level: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 78 dB(A)

Operating voltage (standard): . . . . . . . . . . . . . . . . . . . . . . . . 400 V/3 AC/50 Hz (other voltages possible)

Permissible storage temperature: . . . . . . . . . . . . . . . . . . . . . . . . -25 to +55 °C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (-13° to +131° F)

Permissible operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . 0 to +45 °C

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (32° to +113°F)

SM4-618

Technical data 7-1

Page 43