3.2 Environmental conditions and reliability
Table 3.2 Environmental conditions and reliability
| Item |
| Ultrastar |
| Ultrastar | |
Environmental |
| operating | 5 to 55°C |
| ||
conditions | Temperature |
| ||||
|
| storage/shipping |
| |||
| Temperature gradient | 20°C per hour maximum | ||||
| Humidity | operating | 5 to 90%RH |
| ||
|
| 5 to 90%RH |
| |||
| Wet bulb temperature | 29°C maximum (non condensing) | ||||
| Atmosphere |
| No corrosive gas, saline atmosphere | |||
|
|
| or | |||
|
|
| (Example. organic silicon,organic tin) | |||
| Altitude | operating |
| |||
|
|
| ||||
| Magnetic field |
| 400 micro Tesla maximum | |||
Shock and | Vibration | operating | 9.8 m/s2(1.0G) maximum | |||
vibration | (see Note 6) | 49 m/s2(5.0G) maximum | ||||
| Shock | operating | 147 m/s2(15G) maximum | [11ms] | ||
| (see Note 7) | 735 m/s2(75G) maximum | [11ms] | |||
|
|
| 2450m/s2(250G) maximum | [2ms] | ||
Acoustic noise | Acoustic noise (see Note 8) | 3.7 bel average |
| 3.6 bel average | ||
Reliability | Data Reliability (see Note 9) | Recoverable error: | 10 error in 1012bits read | |||
|
|
| ||||
| Seek error rate (see Note 9) | 10 errors in 108 seeks | ||||
(see Note 10) | Life |
| 5 years (Surface temperature of HDA is 45°C or less) | |||
|
|
| Life of the drive does not change in the case that the | |||
|
|
| drive is used intermittently. (See section 8.6) | |||
| MTBF (see Note 11) | Expected 1,200,000 hours |
|
Drawing No. Sheet No. Revision 5 | ||
K6602906 | 11/46 | 2003/6/12 |