12.2 Jumper socket setting

12.2 Jumper socket setting

The Jumper sockets should be set only when the power is off.

12.2.1SCSI ID WIDE LVD

No.

 

Option Jumper Connector (C3)

SCSI ID #

0

1

Remove all Jumper Sockets

0

 

2

(Default)

 

1

1

Install the Jumper Socket

1

2

for C3-7,8

 

 

2

1

Install the Jumper Socket

2

2

for C3-5,6

 

 

3

1

Install the Jumper Sockets

3

2

for C3-5,6 & 7,8

 

 

4

1

Install the Jumper Socket

4

2

for C3-3,4

 

 

5

1

Install the Jumper Sockets

5

2

for C3-3,4 & 7,8

 

 

6

1

Install the Jumper Sockets

6

2

for C3-3,4 & 5,6

 

 

7

1

Install the Jumper Sockets

7

2

for C3-3,4 & 5,6 & 7,8

 

 

8

1

Install the Jumper Socket

8

2

for C3-1,2

 

 

9

1

Install the Jumper Sockets

9

2

for C3-1,2 & 7,8

 

 

10

1

Install the Jumper Sockets

10

2

for C3-1,2 & 5,6

 

 

11

1

Install the Jumper Sockets

11

2

for C3-1,2 & 5,6 & 7,8

 

 

12

1

Install the Jumper Sockets

12

2

for C3-1,2 & 3,4

 

 

13

1

Install the Jumper Sockets

13

2

for C3-1,2 & 3,4 & 7,8

 

 

14

1

Install the Jumper Sockets

14

2

for C3-1,2 & 3,4 & 5,6

 

 

15

1

Install the Jumper Sockets

15

2

for C3-1,2 & 3,4 & 5,6 & 7,8

 

 

Note.1 Jumpers are installed at C3-2,4 & 6,8 & 10,12 & 14,16 & 18,20 as spares. Customer can remove and use them for another jumper settings.

Drawing No. Sheet No. Revision 5

K6602906 41/46 2003/6/12

Page 41