Hitachi HUS157336EL3800 Disable Auto Start WIDE LVD, SCA-2 LVD, Drawing No. Sheet No. Revision

Models: HUS157373EL3800 HUS157373EL3600 HUS157336EL3600 HUS157336EL3800

1 46
Download 46 pages 50.66 Kb
Page 43
Image 43
12.2.3Disable Auto Start

12.2.3Disable Auto Start

WIDE LVD

No.

Option Jumper Connector (C3)

Meaning

1

Remove the Jumper Socket

Spindle motor automatically

starts when the power is

 

for C3-9,10 (Default)

 

 

 

applied or in sequence via ID

 

 

 

 

 

1

9

23

number x 10 seconds from the

 

time power is applied if

 

 

 

 

 

 

 

 

C3-13,14 is jumpered.

 

2

10

24

 

2

Install the Jumper Socket

Spindle motor starts only

 

for C3-9,10

 

by SCSI command

 

1

9

23

 

 

2

10

24

 

SCA-2 LVD

No.

Option Jumper Connector (C3)

Meaning

1

Remove the Jumper Socket

(If AUTO START in SCSI bus

connector (C1) is open,)

 

for C3-9,10 (Default)

 

 

 

Spindle motor automatically

 

 

 

 

 

1

9

23

starts when the power is

 

applied or in sequence via ID

 

 

 

 

 

 

 

 

number x 10 seconds from the

 

 

 

 

time power is applied if

 

2

10

24

C3-9,10 is jumpered.

 

(If AUTO START in SCSI bus

 

 

 

 

 

 

 

 

connector (C1) is grounded,)

 

 

 

 

Spindle motor starts only by

 

 

 

 

SCSI command.

2

Install the Jumper Socket

Spindle motor starts only by

 

for C3-9,10

 

SCSI command regardless of

 

1

9

23

AUTO START setting in SCSI

 

bus connector (C1).

 

 

 

 

 

2

10

24

 

Drawing No. Sheet No. Revision 5

K6602906

43/46

2003/6/12

Page 43
Image 43
Hitachi HUS157336EL3800 Disable Auto Start WIDE LVD, SCA-2 LVD, Drawing No. Sheet No. Revision, K6602906, 43/46, 2003/6/12