Moxa Technologies EDS-405A Explanation of “Settings” Items, Redundancy Protocol, Set as Master

Models: EDS-405A EDS-408A

1 82
Download 82 pages 15.35 Kb
Page 39
Image 39

EDS-408A/405A Series User’s Manual

Featured Functions

Explanation of “Settings” Items

 

 

Redundancy Protocol

 

 

 

 

Setting

Description

Factory Default

 

 

Turbo Ring

Select this item to change to the

 

 

 

Turbo Ring configuration page.

 

 

 

 

 

 

 

Turbo Ring V2

Select this item to change to the

 

 

 

Turbo Ring V2 configuration page.

None

 

 

 

 

 

RSTP (IEEE

Select this item to change to the

 

 

 

802.1W/1D)

RSTP configuration page.

 

 

 

None

Ring redundancy is not active

 

 

Set as Master

 

 

 

 

 

 

 

 

Setting

Description

Factory Default

 

 

Enabled

Select this EDS as Master

Not checked

 

 

Disabled

Do not select this EDS as Master

 

 

 

 

Redundant Ports

 

 

 

 

Setting

Description

Factory Default

 

 

1st Port

Select any port of the EDS to be

EDS-405A: port 4

 

 

one of the redundant ports.

EDS-408A: port 7

 

 

 

 

 

2nd Port

Select any port of the EDS to be

EDS-405A: port 5

 

 

one of the redundant ports.

EDS-408A: port 8

 

 

 

 

Enable Ring Coupling

 

 

 

 

Setting

Description

Factory Default

 

 

Enable

Select this EDS as Coupler

Not checked

 

 

Disable

Do not select this EDS as Coupler

 

 

 

 

Coupling Port

 

 

 

 

Setting

Description

Factory Default

 

 

Coupling Port

Select any port of the EDS to be the

EDS-405A: port 2

 

 

coupling port

EDS-408A: port 5

 

 

 

 

Coupling Control Port

 

 

 

 

 

 

 

 

Setting

Description

Factory Default

 

 

Coupling Control Port

Select any port of the EDS to be the

EDS-405A: port 3

 

 

 

coupling control port

EDS-408A: port 6

 