Moxa Technologies EDS-405A Syslog Server, 3-56, EDS-408A/405A Series User’s Manual, Setting

Models: EDS-405A EDS-408A

1 82
Download 82 pages 15.35 Kb
Page 71
Image 71
Syslog Server 1

EDS-408A/405A Series User’s Manual

Featured Functions

Syslog Server 1

 

 

Setting

Description

Factory Default

IP Address

Enter the IP address of 1st Syslog Server used by your

None

 

network.

 

Port Destination

Enter the UDP port of 1st Syslog Server.

514

(1 to 65535)

 

 

Syslog Server 2

 

 

Setting

Description

Factory Default

IP Address

Enter the IP address of 2nd Syslog Server used by your

None

 

network.

 

Port Destination

Enter the UDP port of 2nd Syslog Server.

514

(1 to 65535)

 

 

 

Syslog Server 3

 

 

 

 

 

Setting

 

Description

Factory Default

 

 

IP Address

 

Enter the IP address of 3rd Syslog Server used by your

None

 

 

 

 

 

network.

 

 

 

Port Destination

 

Enter the UDP port of 3rd Syslog Server.

514

 

 

(1 to 65535)

 

 

 

 

 

 

 

NOTE

The following events will be recorded into the EDS-408A/405A’s Event Log table, and will then

 

 

be sent to the specified Syslog Server:

 

 

 

1.

Cold start

 

 

 

 

2.

Warm start

 

 

 

 

3.

Configuration change activated

 

 

 

4.

Power 1/2 transition (Off Æ On), Power 1/2 transition (On Æ Off)

 

 

 

5.

Authentication fail

 

 

 

6.

Topology changed

 

 

 

7.

Master setting is mismatched

 

 

 

8.

DI 1/2 transition (Off Æ On), DI 1/2 transition (On Æ Off)

 

 

 

9.

Port traffic overload

 

 

 

10.

dot1x Auth Fail

 

 

 

 

11.

Port link off / on

 

 

 

 

 

 

 

 

 

3-56

Page 71
Image 71
Moxa Technologies EDS-405A user manual Syslog Server, 3-56, EDS-408A/405A Series User’s Manual, Featured Functions, Setting