Using Event Log

EDS-408A/405A Series User’s Manual

Featured Functions

Using Event Log

Bootup

This field shows how many times the EDS has been rebooted or cold

started.

 

Date

The date is updated based on how the current date is set in the “Basic

Setting” page.

 

Time

The time is updated based on how the current time is set in the “Basic

Setting” page.

 

System Startup Time

The system startup time related to this event.

 

 

Events

Events that have occurred.

Events are logged in the EDS-408A/405A Event Log when the following events occur:

1.Cold start

2.Warm start

3.Configuration Change Activated

4.Power Transition from OFF to ON or from ON to OFF

5.Authentication Fail

6.Topology Changed

7.Master Setting is Mismatched

8.Port Traffic Overload

9.Port Link from OFF to ON or from ON to OFF

Using Syslog

This function provides the event logs for the syslog server. The function supports 3 configurable syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent as a syslog UDP packet to the specified syslog servers.