Moxa Technologies EDS-405A, EDS-408A Relay Warning Events Settings, Activate your settings, 3-48

Models: EDS-405A EDS-408A

1 82
Download 82 pages 15.35 Kb
Page 63
Image 63
2.Activate your settings

EDS-408A/405A Series User’s Manual

Featured Functions

2.Activate your settings

After configuring, you will need to activate your EDS’s Relay Event Types.

Relay Warning Events Settings

NOTE: The user interface for the EDS-408A shows 8 ports.

Event Types

Event Types can be divided into two basic groups: System Events and Port Events. System Events are related to the overall function of the switch, whereas Port Events are related to the activity of a specific port.

The EDS supports one relay output. You can configure which relay output is related to which events. This helps administrators identify the importance of the different events.

System Event

Warning Relay output is triggered when…

Power Transition (OnÆOff)

EDS is powered up.

Power Transition (OffÆOn)

EDS is powered down.

Turbo Ring Break (Ring Master

When the EDS-408A/405A is the

Only)

Master of this Turbo Ring, and the

 

Turbo Ring is disconnected.

NOTE

If the Turbo Ring Switch function is enabled, and the Turbo Ring DIP Switch is set to “ON”, the

 

Turbo Ring Break Event cannot be changed. If not, the Turbo Ring Break Event can be set by

 

using a web browser.

 

 

 

 

NOTE

The Turbo Ring Break Warning will be automatically enabled when the following configuration

 

is set:

 

1.

Turbo Ring DIP Switch functions are enabled.

 

2.

The Hardware Turbo Ring DIP Switch is set to “ON”.

 

3.

The Master DIP Switch is set to “ON”.

Please refer to “Configuring Basic SettingsTurbo Ring DIP Switch” for more details.

3-48

Page 63
Image 63
Moxa Technologies EDS-405A Relay Warning Events Settings, Activate your settings, Warning Relay output is triggered when…