Moxa Technologies EDS-405A SNMP Read/Write Settings, SNMP Versions, V1, V2c Read Community, 3-16

Models: EDS-405A EDS-408A

1 82
Download 82 pages 15.35 Kb
Page 31
Image 31
SNMP Read/Write Settings

EDS-408A/405A Series User’s Manual

Featured Functions

SNMP Read/Write Settings

SNMP Versions

Setting

Description

 

Factory Default

V1, V2c, V3

Select SNMP protocol versions V1, V2c,

 

 

V3 to manage the switch

 

 

 

 

 

V1, V2c

Select SNMP protocol versions V1, V2c to

 

V1, V2c

 

manage the switch

 

 

V3 only

Select only SNMP protocol version V3 to

 

 

manage the switch

 

 

 

 

 

V1, V2c Read Community

 

 

 

 

 

 

 

Setting

Description

 

Factory Default

 

Use a community string match for

 

 

V1, V2c Read

authentication. This means that the SNMP

 

public

Community

agent accesses all objects with read-only

 

Maximum 30 characters

permissions using the community string

 

 

 

 

 

public.

 

 

V1, V2c Write/Read Community

 

 

Setting

Description

 

 

Factory Default

V1, V2c

Uses a community string match for

 

 

 

authentication, which means that SNMP

 

private

Read/Write

servers access all objects with read/write

 

 

Maximum 30 characters

Community

permissions using the community string

 

 

 

 

 

private.

 

 

 

For SNMP V3, there are two levels of privilege for different accounts to access the EDS. Admin privilege allows access, and authorization to read and write the MIB file. User privilege only allows reading the MIB file, but does not authorize writing.