Hitachi HV-D37A, HV-D27A External Trigger, Camera Sync, SYNC reset timing, Next SYNC Reset timing

Models: HV-D27A HV-D37A

1 82
Download 82 pages 3.98 Kb
Page 48
Image 48
EXTERNAL TRIGGER

Note: Prohibited period of the external trigger pulse timing

For each external trigger mode, when the end edge of external trigger pulse is input in the prohibited period (shown in the under figure), the picture is not output after the SYNC reset.

Please input the repetition period of trigger pulse with the following specification, to avoid the trigger input to an above prohibited period.

The period of the next end edge trigger pulse from the previous end edge of trigger CCD MODE: FLD, except from nV to nV+2H

CCD MODE: FRM, except from 2nV to 2nV+2H (V: a vertical synchronous period, n: an integer)

EXTERNAL TRIGGER

nV

CAMERA SYNC

SYNC reset timing

Next SYNC Reset timing

Prohibited period of the end edge of external trigger pulse (1H period before the start of camera V SYNC)