Hitachi series inverter manual Intelligent Input Terminal Listing, Symbol Code Input Terminal Name

Models: series inverter

1 34
Download 34 pages 32.7 Kb
Page 30
Image 30

Intelligent Input Terminal Listing

Symbol

Code

Input Terminal Name

 

 

 

 

 

 

FW

00

Forward Run/Stop

 

 

 

RV

01

Reverse Run/Stop

 

 

 

CF1

02

Multi-speed select, Bit 0 (LSB)

 

 

 

CF2

03

Multi-speed select, Bit 1

 

 

 

CF3

04

Multi-speed select, Bit 2

 

 

 

CF4

05

Multi-speed select, Bit 3 (LSB)

 

 

 

JG

06

Jogging

 

 

 

DB

07

External DC braking

 

 

 

SET

08

Set (select) second motor data

 

 

 

2CH

09

2-stage accel and decel

 

 

 

FRS

11

Free-run stop

 

 

 

EXT

12

External trip

 

 

 

USP

13

Unattended start protection

 

 

 

SFT

15

Software lock

 

 

 

AT

16

Analog input voltage/current sel.

 

 

 

RS

18

Reset inverter

 

 

 

PTC

19

PTC thermistor thermal protection

 

 

 

STA

20

Start (3-wire interface)

 

 

 

STP

21

Stop (3-wire interface)

 

 

 

F/R

22

FWD, REV (3-wire interface)

 

 

 

PID

23

PID disable

 

 

 

PIDC

24

PID Reset

 

 

 

UP

27

Remote control Up func.

 

 

 

DWN

28

Remote control Down func.

 

 

 

UDC

29

Remote control data clearing

 

 

 

OPE

31

Operator control

 

 

 

ADD

50

Add frequency enable

 

 

 

F-TM

51

Force Terminal Mode

 

 

 

RDY

52

Quick Start Enable

 

 

 

S-ST

53

Special-Set (select) 2nd motor data

 

 

 

255

Not selected

 

 

 

28

Page 30
Image 30
Hitachi series inverter manual Intelligent Input Terminal Listing, Symbol Code Input Terminal Name