GM-51 5-inch viewfinder attachment

Use the separately sold AT-30 viewfinder adapter when installing the GM-51 5-inch viewfinder.

1.Raise the lock lever of the AT-30 horizontally and remove the viewfinder mounting screw from the AT-30. Insert this screw in the bottom of the GM-51. Insert the screw together with the GM-51 into the AT-30 and set the lock lever forward, then turn the lever clockwise to secure it.

Warning: Be sure to tilt the lock lever forward and turn it clockwise to tighten it. If tightening is overlooked, the GM-51 can drop and pose a risk of injury.

2.Insert the GM-51 and AT-30 into the slot at the rear of the handle and slide them forward until a latching sound is heard from the release knob.

Warning: Press the release knob to where a latching sound is audible. If not securely attached, the entire viewfinder can drop and pose a risk of injury.

Set lock lever B of the AT- 30 rearward.

Turn lock lever B clockwise and check for absence of wobble at the AT-30 mounting.

Connect the viewfinder cable to the camera viewfinder connector.

22

Page 33
Image 33
Hitachi V-21W operating instructions GM-51 5-inch viewfinder attachment