3. Air hose

Air hose must have a minimum working pressure rating of 150 psi (10.4 bar 10.6 kgf/cm2) or 150% of the maximum pressure produced in the system, whichever is higher.

4. Hose coupling

The Nailer can be installed as follows: Remove the dust cap placed at the air inlet. Install a 3/8 NPT male plug at the air inlet.

Dust Cap

3/8 NPT Male Plug

A female coupler must be on the air hose.

The hose coupling (male plug-female coupler) must remove all pressure from the Nailer when disconnected.

Never use a non relieving coupler on the Nailer.

5. Air consumption

Using the Air consumption table and the Air compressor size formula, find a correct compressor size.

Air consumption table

 

psi

80

90

100

Operating pressure

(bar)

(5.5)

(6.2)

(6.9)

 

(kgf/cm2)

(5.6)

(6.3)

(7)

 

 

 

 

 

 

 

 

NV83A2

.062

.073

.084

 

 

(1.8)

(2.1)

(2.4)

Air consumption

 

 

 

 

 

 

 

 

 

.048

.061

.075

ft3/cycle

 

NV65AC

 

(1.4)

(1.7)

(2.1)

(ltr/cycle)

 

 

 

 

 

 

 

NV50A1

.025

.030

.035

 

 

(.71)

(.85)

(.99)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air compressor size formula Amount of air required =number of Nailers

average nails driven each minute per Nailer

air consumption at given air pressure

safety factor (always 1.2)

Example: 2 Nailers (NV83A2) operating at 100 psi driving 30 nails per minute

Amount of air required =2 30 .084 (2.4) 1.2

=6.0 CFM (ft3/min) (173 ltr/min)

After making the calculations as shown above, you should find a compressor providing 6.0 CFM of air that is required.

English

LUBRICATION

It is important that the Nailer be properly lubricated. Without proper lubrication, the Nailer will not work properly and parts will wear prematurely.

Use Hitachi pneumatic tool lubricant.

Do not use detergent oil or additives. These lubricants will harm the O-rings and other rubber parts. This will cause the Nailer to malfunction.

Filter-regulator-lubricator units should always be used.

Keep the lubricator filled with Hitachi pneumatic tool lubricant.

If a lubricator is not available, supply 5 – 10 drops of Hitachi pneumatic tool lubricant into the air plug on the Nailer twice a day.

COLD WEATHER CARE

Do not store the Nailer in a cold weather environment. Keep the Nailer in a warm area until beginning the work.

If the Nailer is already cold, bring it in a warm area and allow the Nailer to warm up before use.

1Reduce the air pressure to 64 psi (4.4 bar 4.5 kgf/cm2).

2Remove all nails from the Nailer.

3Connect the air hose and free-fire (blank-fire) the Nailer.

The lowered air pressure will be enough to free- fire the Nailer.

Slow speed operation tends to warm up the moving part.

CAUTION

Do not free-fire the Nailer at high pressure.

TESTING THE NAILER

DANGER

Operators and others in work area MUST wear safety glasses with side shields which conforms to ANSI Z87.1 specifications.

WARNING

Never use Nailer unless push lever is operating properly.

Before actually beginning the nailing work, test the Nailer by using the check list below. Conduct the tests in the following order.

If abnormal operation occurs, stop using the Nailer and contact a Hitachi authorized service center immediately.

— 11 —

Page 11
Image 11
Hitachi Koki USA NV 50A1, NV65AC, NV83a2 manual Lubrication, Cold Weather Care, Testing the Nailer