English
OPTIONAL ACCESSORIES
... sold separately
◯Sequential Trip Mechanism Kit (Code No. 876762) (Single Shot Parts)
◯Pneumatic Tool Lubricant
.8 oz. (25 cc) oil feeder | (Code No. 877153) |
4 oz. (120 cc) oil feeder | (Code No. 874042) |
1 quart (1 ltr) can | (Code No. 876212) |
NOTE: Accessories are subject to change without any obligation on the part of HITACHI.
AIR SUPPLY
DANGER
⬤ NEVER use oxygen or other bottled gases. Explosion may occur.
APPLICATIONS
<NV83A2, NV65AC>
◯Construction wooden work such as floor and wall framing, roof decking, subflooring.
◯Mobile and modular home construction.
◯Making wooden boxes, palletes, and drums.
◯Packing operations in manufacturing plants, and other types of packing and crating work in general.
<NV50A1>
◯Making wooden boxes, and light pallets.
◯Making wooden furniture, wooden sash, and other wooden products.
◯Packing operations in manufacturing plants, and other types of packing and crating work in general.
◯Construction work in general such as prefabricated houses.
NOTE:
◯Aluminium nails may bend when used on hard surfaces.
Test before use.
BEFORE OPERATION
Read section titled “SAFETY” (pages 4 – 7).
Make sure of the followings before operation.
WORKING ENVIRONMENT
WARNING
⬤No flammable gas, liquid or other flammable objects at worksite.
⬤Clear the area of children or unauthorized personnel.
WARNING
⬤Never connect Nailer to pressure which
potentially exceeds 200 psi (13.7 bar 14 kgf/cm2).
⬤ Never use non relieving coupler on Nailer.
1.Power source
◯Use only clean, dry, regulated compressed air as a power source for this Nailer.
◯Air compressors used to supply compressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 “Safety Standard For Compressors For Process Industries.”
◯Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer.
Drain daily.
2. Filter-Regulator-Lubricator
◯Use a regulator with a pressure range of 0 – 120 psi
(0 – 8.3 bar 0 – 8.5 kgf/cm2).
◯
Filter ............. The filter removes moisture and dirt mixed in compressed air.
Drain daily unless fitted with an automatic drain.
Keep the filter clean by regular maintenance.
Regulator ..... The regulator controls the operating pressure for safe operation of the Nailer. Inspect the regulator before operation to be sure it operates properly.
Lubricator .... The lubricator supplies an oil mist to the Nailer.
Inspect the lubricator before operation to be sure the supply of lubricant is adequate.
Use Hitachi pneumatic tool lubricant.
Regulator
Nailer Side Compressor Side
Filter
Lubricator
— 10 —