Electric Booster Water Heater Option

Electric Booster Water Heater Option

NOTE: Electric Booster electrical connection will be separate from the dishwasher electrical connection unless single point electrical connection is supplied. If circuit breaker option is provided, the electric supply or supplies are connected to the circuit breaker box on top of the dishwasher.

Refer to Electrical Data, page 12. Before making electrical connection, test the electrical service to assure that it agrees with the specifications on the Electric Booster data plate (Fig. 6). Also, refer to the wiring diagram attached inside the cover of the Electric Booster.

A fused disconnect switch or circuit breaker (if not supplied) must be installed in the electrical service line supplying this booster and should meet the requirements of your local electrical code.

If the booster electrical connections are separate, they are made to the contactor in the booster. If grounding is not provided by the conduit used, connect the ground lead to the grounding lug provided (Fig. 6).

Fig. 6

OPTIONAL EQUIPMENT CONTROL CONNECTIONS

NOTE: The 78" plugged holes in the side of the control box are for detergent and chloritizer / rinse feeder connections only. If detergent and chloritizer / rinse feeder electrical connections are required, remove the plug buttons(s) and connect through the hole(s) provided.

Detergent Dispenser

Maximum rating for detergent dispenser connected to DPS1 and DPS2 is 1.5 Amps at line voltage.

Rinse Aid Dispenser

Maximum rating for rinse aid dispenser connected to RPS1 and RPS2 is 1.5 Amps at line voltage.

Vent Fan Control

The maximum rating for a vent fan control relay connected to terminals 4 and 6 is either 30 Amps at 120 Volts (1.5 HP) or 25 Amps at 277 Volts (3.0 HP). The vent fan control relay provides switch contacts only and does not provide the power supply for the vent fan motor. When the dishwasher is connected to the vent fan, the vent fan is switched on when the dishwasher is on, and off when the dishwasher is off.

Hobart Infrared Booster Gas Water Heater

The maximum rating for connecting a Hobart Model IB57 Dishwasher Activated infrared gas booster water heater to BSTR1 and BSTR2 is 0.5 Amp at 24 Volts. If a Stand Alone Booster Heater is used, no electrical connection to the dishwasher is allowed. Refer to the Infrared Booster Gas Water Heater Manual for additional installation details.

– 11 –