10-3-5. Piping and Drain Hose Installation

Terminal cover

Screw

Screw

Terminal block

Earth wire

10-3-5. Piping and Drain Hose Installation

Piping and drain hose forming

Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately.

(Use polyethylene foam as insulating material.)

Rear right

Cord clamp

Connecting cable

Fig. 10-3-6

Rear left

Bottom left

Left

Bottom right

Right

Front panel slit

Die-cutting

Changing drain hose

Piping preparation

Terminal block

Earth wire (loop)

Earth screw

Fig. 10-3-7

Fig. 10-3-10

1.Die-cutting front panel slit

Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers.

2.Changing drain hose

For left connection, left-bottom connection and rear-left connection’s piping, it is necessary to relocate the drain hose and drain cap.

Connecting cable

About 15 cm

Fig. 10-3-8

110mm

Earth line

10mm

10mm

50mm

Fig. 10-3-9

NOTE :

Connecting cable (Indoor unit/outdoor unit)

Wire type: H07RN-F or 60245IEC66 (1.0 mm²)

How to remove the drain cap

Clip drain cap with needle-nose pliers, and pull out.

Fig. 10-3-11

How to remove the drain hose

The drain hose is secured in place by a screw.

Remove the screw securing the drain hose, then pull out the drain hose.

Screw

Drain hose

 

Fig. 10-3-12