Toshiba RAS-B10SKVP-E Item, Operation flow and applicable data, etc, Description, Purpose

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 46
Image 46

 

Item

 

 

Operation flow and applicable data, etc.

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19. Outdoor

 

<With Quiet control/Non-select method>

 

 

 

1. Purpose

 

 

 

 

 

Quiet control

 

 

 

 

 

 

 

 

For the users who concern about noise of

 

 

 

 

 

Select “Control” or “No control” by keeping

 

 

 

 

 

 

 

 

 

 

 

the outdoor unit, this control controls the

 

 

 

 

 

[RESET] button pushed for 20 seconds.

 

 

 

 

max. revolutions of the compressor to

 

 

 

 

 

(“No control” at shipment from the factory)

 

 

 

reduce the noise.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To reduce noise, [RESET] button of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchanging from “No control” to “Control”:

 

 

 

indoor unit is kept pushed for 20 seconds.

 

 

 

 

 

Beep sound is heard (Pi, Pi, Pi, Pi, Pi) and

 

 

 

The number of revolution for the indoor fan

 

 

 

 

 

the operation LED 5Hz flashes for 5 seconds.

 

 

motor and the setup temp value are kept as

 

 

 

 

 

• Exchanging from “Control” to “No control”:

 

 

 

they are.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Beep sound is heard.

 

 

 

 

 

3. Operation

 

 

 

 

 

 

 

 

 

(Operation LED does not flash.)

 

 

 

 

As shown in the table, the maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

revolution number of indoor unit compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

can be reduced.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

As the maximum number of revolution of the

 

 

 

 

 

 

 

 

 

 

 

 

 

compressor is restricted, the rise-up

 

 

 

 

 

 

 

 

 

 

 

 

 

performance at the start time is weakened.

 

 

 

 

 

 

 

 

 

 

 

 

 

<Maximum number of revolution of compressor at normal time and Quiet control time>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAS-B10SKVP-E

 

 

RAS-B13SKVP-E

RAS-B16SKVP-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside temp.

Normal time

Quiet controlled

 

Normal time

Quiet controlledd

Normal time

Quiet controlled

 

 

 

 

 

 

(TO)

(rps)

(rps)

 

 

(rps)

(rps)

(rps)

(rps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

59

50

 

 

86

 

 

74

98

 

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–5°C ~

76

65

 

 

76

 

 

65

92

 

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

–10 ~ –5°C

76

65

 

 

76

 

 

65

92

 

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~ –10°C

76

65

 

 

76

 

 

65

92

 

78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAS-10SKVP-ND

 

 

RAS-13SKVP-ND

RAS-16SKVP-ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outside temp.

Normal time

Quiet controlled

 

Normal time

Quiet controlled

Normal time

 

Quiet controlled

 

 

 

 

 

 

(TO)

(rps)

(rps)

 

 

(rps)

(rps)

(rps)

 

(rps)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

59

50

 

 

86

 

 

74

98

 

83

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

–5°C ~

76

76

 

 

76

 

 

76

92

 

92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

–10 ~ –5°C

85

76

 

 

90

 

 

76

93

 

92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

~ –10°C

93

76

 

 

103

 

 

76

105

 

92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

– 46 –