Toshiba RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-10SAVP-E service manual 100, Requirement

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 100
Image 100
Requirement

No.

Part name

 

Procedure

Remarks

ƒ

Inverter

1)

Perform work of item 1 in .

Inverter cover

 

assembly

2)

Remove screw (ST1TØ4 × 8L 2 pcs.) of the

 

 

P. C. board

 

 

 

upper part of the front cabinet.

 

 

 

(Soldered surface)

 

 

 

 

• If removing the inverter cover in this condition, P.C. board can be checked.

• If there is no space above the unit, perform work of 1 in .

Be careful to check the inverter because high-voltage circuit is incorporated in it.

3) Perform discharging by connecting ,

Discharging position

Plug of

soldering

polarity by discharging resistance (approx.

(Discharging period

iron

10 seconds or more)

10040W) or plug of soldering iron to ,

 

 

 

terminals a of the C14 (printed “CAUTION

 

 

HIGH VOLTAGE” is attached.) electrolytic

 

 

capacitor (760µF) on P.C. board.

 

 

Be careful to discharge the capacitor

 

 

because the electrolytic capacitor

 

 

cannot naturally discharge and voltage

 

 

remains according to trouble type in

A screw

 

some cases.

Terminal block

(STIT-4X8MSZN)

NOTE

This capacitor is one with mass capacity. Therefore, it is dangerous that a large spark generates if short-circuiting between – 100 –, Manual background polarity with screwdriver, etc. for discharging.

4)

Remove screw (ST1TØ4 × 8L 2 pcs.) fixing

 

 

 

the main body and the inverter box.

Put the compressor

Put each leads

5)

Remove the front cabinet by performing step

leads through

through the hole

the hole

 

 

1 in , and remove the fixing screws

 

 

 

 

 

(ST1TØ4 × 8L) for securing the main body

 

 

 

and inverter box.

The connector is one

6)

Remove various lead wires from the holder

with lock, so remove

 

at upper part of the inverter box.

it while pushing the

 

7)

Pull the inverter box upward.

part indicated by

 

an arrow.

 

8)

Disconnect connectors of various lead wires.

 

 

 

Requirement

As each connector has a lock mecha- nism, avoid to remove the connector by holding the lead wire, but by holding the connector.

Be sure to remove the connector by holding the connector, not by pulling the lead wire.

– 100 –

Page 100
Image 100