No.

Part name

 

Procedure

Remarks

ƒ

Inverter

1)

Perform work of item 1 in .

Inverter cover

 

assembly

2)

Remove screw (ST1TØ4 × 8L 2 pcs.) of the

 

 

P. C. board

 

 

 

upper part of the front cabinet.

 

 

 

(Soldered surface)

 

 

 

 

• If removing the inverter cover in this condition, P.C. board can be checked.

• If there is no space above the unit, perform work of 1 in .

Be careful to check the inverter because high-voltage circuit is incorporated in it.

3) Perform discharging by connecting ,

Discharging position

Plug of

soldering

polarity by discharging resistance (approx.

(Discharging period

iron

10 seconds or more)

10040W) or plug of soldering iron to ,

 

 

 

terminals a of the C14 (printed “CAUTION

 

 

HIGH VOLTAGE” is attached.) electrolytic

 

 

capacitor (760µF) on P.C. board.

 

 

Be careful to discharge the capacitor

 

 

because the electrolytic capacitor

 

 

cannot naturally discharge and voltage

 

 

remains according to trouble type in

A screw

 

some cases.

Terminal block

(STIT-4X8MSZN)

NOTE

This capacitor is one with mass capacity. Therefore, it is dangerous that a large spark generates if short-circuiting between , polarity with screwdriver, etc. for discharging.

4)

Remove screw (ST1TØ4 × 8L 2 pcs.) fixing

 

 

 

the main body and the inverter box.

Put the compressor

Put each leads

5)

Remove the front cabinet by performing step

leads through

through the hole

the hole

 

 

1 in , and remove the fixing screws

 

 

 

 

 

(ST1TØ4 × 8L) for securing the main body

 

 

 

and inverter box.

The connector is one

6)

Remove various lead wires from the holder

with lock, so remove

 

at upper part of the inverter box.

it while pushing the

 

7)

Pull the inverter box upward.

part indicated by

 

an arrow.

 

8)

Disconnect connectors of various lead wires.

 

 

 

Requirement

As each connector has a lock mecha- nism, avoid to remove the connector by holding the lead wire, but by holding the connector.

Be sure to remove the connector by holding the connector, not by pulling the lead wire.

– 100 –

Page 100
Image 100
Toshiba RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-10SAVP-E service manual 100, Some cases, STIT-4X8MSZN

RAS-10SAVP-E, RAS-B10SKVP-E, RAS-B13SKVP-E specifications

Toshiba has established itself as a leader in the HVAC market, known for its innovative technologies and reliable performance. Among its range of air conditioning units, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E models stand out for their efficiency and advanced features.

The Toshiba RAS-B10SKVP-E is designed for optimal cooling and heating efficiency, making it an ideal choice for small to medium-sized rooms. One of its main features is the Super Hi-M-PAM inverter technology, which enhances energy savings by continuously adjusting the compressor speed to match the cooling demand. This results in lower energy consumption while maintaining a stable temperature. Additionally, the unit boasts a 4-in-1 operation mode that allows users to select cooling, heating, dehumidification, or ventilating modes, ensuring maximum comfort at all times.

Similarly, the RAS-10SAVP-E model incorporates advanced features such as an eco-friendly refrigerant, R32, which has a lower Global Warming Potential (GWP) compared to traditional refrigerants. This model is equipped with a high-efficiency filter that captures dust and allergens, ensuring cleaner air quality. The sleek design allows for easy integration into various interior styles, while its quiet operation makes it a preferred choice for residential environments.

The RAS-B13SKVP-E model takes performance to the next level with a robust cooling capacity, designed for larger spaces. This model utilizes Toshiba's unique DC Hybrid Inverter technology, which not only enhances cooling efficiency but also facilitates faster temperature control. A notable characteristic of this unit is its wide-angle air distribution system, which allows for even airflow throughout the room, enhancing comfort.

In addition to these features, all three models are equipped with smart controls that enable users to operate their air conditioning systems remotely via mobile devices. This connectivity adds convenience and ensures that users can manage their indoor climate at their fingertips. They also come with user-friendly interfaces and programmable timers, allowing for personalized comfort settings.

In conclusion, the Toshiba RAS-B10SKVP-E, RAS-10SAVP-E, and RAS-B13SKVP-E air conditioning units combine energy efficiency, innovative technology, and user-friendly features to deliver exceptional indoor comfort. With their advanced technologies, these models are ideal choices for anyone seeking reliable and effective climate control solutions.