Toshiba RAS-B13SKVP-E No. Part name, Procedures, Remarks, ˆCross flow fan Caution at reassembling

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 96
Image 96
No. Part name

No. Part name

Procedures

Remarks

ˆCross flow fan <Caution at reassembling>

1)At assembling work of the bearing base, check that the drain pipe is surely incorpo- rated in the back body.

(Otherwise, water leak is caused.)

2)To incorporate the fan motor, remove the fan motor rubber (at shaft core side), incorporate the motor into the position in the following figure, and then install the fan motor.

Bearing base

Drain pipe

• Install the cross flow fan so that the right

 

end of the 1st joint from the right of the

 

cross flow fan is set keeping 70.5 mm from

 

wall of rear plate of the main unit.

 

• Holding the set screw, install the cross flow

Joint

fan so that U-groove of the fan motor

 

comes to the mounting hole of the set

 

screw.

 

70.5mm

Perform positioning of the fan motor as follows:

When assembling the fan motor, the fan motor must be installed in such a way that the fan motor leads will be taken out is positioned at the bottom front.

After assembling the two hooking claws of the motor band (right) into the main body, position the fan motor, insert it, and then secure the motor band (right) using the two fixing screws.

U groove

– 96 –

Page 96
Image 96