Toshiba RAS-10SAVP-E 41, Compressor ON, Thermo. OFF, Defrost, Setup value, Power OFF, Item

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 41
Image 41
Compressor ON

Item

Operation flow and applicable data, etc.

 

Description

 

 

 

 

14. Pulse motor

This function controls throttle amount of the refriger-

1)

When starting the operation, move the

valve (PMV)

ant in the refrigerating cycle.

 

valve until it fits to the stopper. (Initialize)

control

According to operating status of the air conditioner,

 

* In this time, “Click” sound may be heard.

 

 

 

this function controls the open degree of valve with

2)

Adjust the open degree of valve by super

 

an expansion valve with pulse motor.

 

 

heat amount. (SH control)

 

 

 

 

 

3) If the discharge temperature was exces-

 

 

sively up, adjust the open degree of valve

 

Starting up

so that it is in the range of set tempera-

 

ture. (Discharge temp. control)

 

 

 

 

4) When defrost operation is performed, the

 

Initialize

open degree of PMV is adjusted accord-

 

ing to each setup conditions; during

 

 

 

 

preparation for defrost or during defrost

 

 

operation (4-way valve is inversed.).

 

Move to initial position

5) When turn off the compressor by thermo.

 

OFF or STOP by remote controller, the

 

 

open degree of the PMV is adjusted to

 

 

the setup valve.

 

 

Compressor ON

SH control

 

Td

 

release control

 

 

 

PMV open degree control

 

Stop by

Thermo. OFF

Defrost

remote controller

 

 

Setup value

Setup value

Setup value

Power OFF

 

 

*SH (Super Heat amount) =

Ts (Temperature of suction pipe of the compressor) –

Tc or Te (Heat exchanger temperature at evaporation side)

*PMV: Pulse Motor Valve