Toshiba RAS-10SAVP-E, RAS-B13SKVP-E 29, Operation flow and applicable data, etc, Description

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 29
Image 29
Item

Item

Operation flow and applicable data, etc.

Description

1.Basic 1. Operation control

operation

Receiving the user’s operation condition setup, the operation statuses of indoor/outdoor units are

 

 

controlled.

 

1)

The operation conditions are selected by the remote controller as shown in the below.

 

2)

A signal is sent by ON button of the remote controller.

 

3)

The signal is received by a sensor of the indoor unit and processed by the indoor controllers as

 

 

shown in the below.

 

4)

The indoor controller controls the indoor fan motor and louver motor.

 

5)

The indoor controller sends the operation command to the outdoor controller, and sends/

 

 

receives the control status with a serial signal.

 

6)

The outdoor controller controls the operation as shown in the left, and also controls the com-

 

 

pressor, outdoor fan motor, 4-way valve and pulse motor valve.

Remote controller

Selection of

operation conditions

ON/OFF

Control contents of remote controller

ON/OFF (Air conditioner/Air purifier)

Operation select (COOL/HEAT/AUTO/DRY)

Temperature setup

Air direction

Swing

Air volume select (AUTO/LOW/LOW+/MED/MED+/HIGH)

Sleep mode

ON timer setup

OFF timer setup

High power

8˚C heat operation (-ND model only)

Indoor unit

Signal receiving

Indoor unit control

Operation command

Serial signal send/receive

Indoor unit control

Command signal generating function of indoor unit operation

Calculation function (temperature calculation)

Activation compensation function of indoor fan

Cold draft preventive function

Timer function

Indoor heat exchanger release control

Indoor fan motor

Louver motor

Outdoor unit

Serial signal send/receive

 

Outdoor unit control

Inverter

 

 

 

• Compressor speed control of inverter output

 

 

 

 

Outdoor unit control

 

• Waveform composite function

 

 

 

 

 

 

• Calculation function

 

 

 

 

 

 

 

(Temperature calculation)

 

 

 

 

• AD conversion function

 

 

 

 

• Quick heating function

 

 

 

 

• Delay function of compressor reactivation

 

 

 

 

• Current release function

 

 

 

 

• GTr over-current preventive function

 

 

 

 

• Defrost operation function

 

 

 

 

 

 

~

Compressor

Outdoor fan motor

4-way valve

Pulse motor valve (P.M.V.)

Freeze prevention heater

(-ND model only)