10-3-7. Drainage

CAUTION

Bind the auxiliary pipes (two) and connecting cable with facing tape tightly.

In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.

10-3-6. Indoor Unit Installation Indoor unit

10-3-7. Drainage

1. Run the drain hose at a downward sloped angle.

NOTE :

Hole should be made at a slight downward slant on the outdoor side.

Do not route the

Do not form the drain hose

drain hose upwards.

into the waved shape.

Auxiliary pipes – 62 –

Installation plate

Connecting cable

50mm or more

Fig. 10-3-18

Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit.

Carefully connect the auxiliary pipes and connecting pipes to each other and cut off the insulating tape wound on the connecting pipe to avoid double-taping at the joint, moreover, seal the joint with the vinyl tape, etc.

Since condensation can result in machine performance trouble, be sure to insulate both connecting pipes. (Use polyethylene foam as insulating material.)

When bending a pipe, be careful not to crush it.

10-3-6. Indoor Unit Installation

1.Pass the pipe through the hole in the wall, and hook the indoor unit on the installation plate at the upper hooks.

2.Swing the indoor unit to right and left to confirm that it is firmly hooked on the installation plate.

3.While pushing the indoor unit onto the wall, hook it at the lower part on the installation plate.

Pull the indoor unit toward you to confirm that it is firmly hooked on the installation plate.

Manual background Hook here

Manual background 1 Installation plate

Hook

Push (unhook)

 

Fig. 10-3-19

For detaching the indoor unit from the installation plate pull the indoor unit toward you while pushing the bottom up at the specified places.

Do not put the

Do not put the drain

drain hose end

hose end in the

into water.

drainage ditch.

Fig. 10-3-21

2.Put water in the drain pan and make sure that the water is being drained outside.

3.When connecting extension drain hose, insulate the connection part of extension drain hose with shield pipe.

Shield pipe

Drain hose Inside the room

 

 

 

Extension drain hose

 

 

Fig. 10-3-22

CAUTION

Install the drain pipe for proper drainage.

Improper drainage can result in water dripping inside the room.

This air conditioner has been designed to drain water collected from condensation which forms on the back of the indoor unit, to the drain pan.

Therefore, do not locate the power cord and other parts at a height above the drain guide.

Wall

Drain guide

Space for pipes

Push

Push

Fig. 10-3-20

Fig. 10-3-23