Toshiba RAS-B10SKVP-E, RAS-B13SKVP-E Control Block Diagram, Indoor Unit, Remote Controller

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 25
Image 25
8. CONTROL BLOCK DIAGRAM

8. CONTROL BLOCK DIAGRAM

8-1. Indoor Unit

RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-B16SKVP-E / RAS-10SKVP-ND, RAS-13SKVP-ND, RAS-16SKVP-ND

Heat Exchanger Sensor (Tcj)

Heat Exchanger Sensor (Tc)

Room Temperature Sensor (Ta) 8-1. Indoor Unit

Infrared Rays Signal Receiver

and Indication

Initializing Circuit

Clock Frequency

Oscillator Circuit

Power Supply

Circuit

M.C.U.

Functions

Cold draft preventing Function

3-minute Delay at Restart for Compressor

Fan Motor Starting Control

Processing

(Temperature Processing)

Timer

Serial Signal Communication

Clean Function

Indoor Unit Control Unit

Louver

Motor

Louver Motor

Drive Control

Indoor Fan

Motor Control

Indoor

Fan Motor

Air purifier unit

Micro Switch

Converter

(D.C circuit)

Noise Filter

From Outdoor Unit

220-240V ~ 50Hz

220V ~ 60Hz (-E model only)

Serial Signal Transmitter/Receiver

Serial Signal Communication

(Operation Command and Information)

Remote Controller Infrared Rays, 36.7kHz

REMOTE CONTROLLER

Operation (START/STOP)

Operation Mode Selection

AUTO, COOL, DRY, HEAT

Thermo. Setting

Fan Speed Selection

ON TIMER Setting

OFF TIMER Setting

Louver AUTO Swing

Louver Direction Setting

SLEEP MODE

Hi POWER

Air Purifier

OFF (1, 3, 5, 9H OFF timer)

8˚C (-ND model only)

– 25 –

Page 25
Image 25
Toshiba RAS-B10SKVP-E, RAS-B13SKVP-E, RAS-10SAVP-E service manual Control Block Diagram, Indoor Unit, Remote Controller