Toshiba RAS-B13SKVP-E, RAS-B10SKVP-E, RAS-10SAVP-E 105, Part name, Procedure, Remarks, •Attachment

Models: RAS-10SAVP-E RAS-B10SKVP-E RAS-B13SKVP-E

1 119
Download 119 pages 48.27 Kb
Page 105
Image 105
•Attachment

No.

Part name

Procedure

Remarks

 

 

 

 

11TE sensor (outdoor heat exchanging temperature sensor)

Attachment

With the leads pointing downward and the sensor leads pointing in the direction shown in the figure, install the sensor onto the straight pipe part of the condenser output pipe.

Detail A

Arrow D

 

Detail C

 

12

TS sensor (Suction pipe temperature sensor)

 

 

• Attachment

 

 

With its leads pointing downward, point the sensor in the

Detail B

 

direction of the packed valve, and install it onto the straight

 

pipe part of the suction pipe.

Detail C

13TD sensor (Discharge pipe temperature sensor)

Attachment

With its leads pointed downward, install the sensor onto the vertical straight pipe part of the discharge pipe.

14TO sensor (Outside air temperature sensor)

Attachment

Insert the outdoor air temperature sensor into the holder, and install the holder onto the heat exchanger.

Detail B

Detail A

Arrow D

TS sensor

TD sensor

TO sensor

CAUTION

During the installation work (and on its completion), take care not to damage the coverings of the sensor leads on the edges of the metal plates or other parts. It is dangerous for these coverings to be damaged since damage may cause electric shocks and/or a fire.

CAUTION

After replacing the parts, check whether the positions where the sensors were installed are the proper positions as instructed. The product will not be controlled properly and trouble will result if the sensors have not been installed in their proper positions.